Microbiol Spectr ; 10(2): e0180721, 2022 04 27.
Article in English | MEDLINE | ID: covidwho-1784772

ABSTRACT

Differential diagnosis of COVID-19 and/or influenza (flu) at point of care is critical for efficient patient management and treatment of both these diseases. The study presented here characterizes the BD Veritor System for Rapid Detection of SARS-CoV-2 and Flu A+B ("Veritor SARS-CoV-2/Flu") triplex assay. The performance for SARS-CoV-2 detection was determined using 298 specimens from patients reporting COVID-19 symptoms within 7 days from symptom onset (DSO) in comparison with the Lyra SARS-CoV-2 RT-PCR (reverse transcriptase PCR) assay ("Lyra SARS-CoV-2") as the reference. The performance for flu A and flu B detection was determined using 75 influenza-positive and 40 influenza-negative retrospective specimens in comparison with the previously FDA-cleared BD Veritor System for Rapid Detection of Flu A+B assay ("Veritor Flu") as the reference. The Veritor SARS-CoV-2/Flu assay met the FDA EUA acceptance criteria (86.7%; 95% confidence interval [95% CI]: 75.8 to 93.1) for SARS-CoV-2 testing compared to Lyra SARS-CoV-2. The Veritor SARS-CoV-2/Flu assay also demonstrated 100% agreement with the Veritor Flu for Flu A+B assay. For flu A detection, the lower bound of the 95% CI was 91.2%; for flu B detection, the lower bound was 90.0%. The dual detection capability of Veritor SARS-CoV-2/Flu for the etiologic agents causing COVID-19 and flu will allow efficient differentiation between the two illnesses, inform disease management, and facilitate optimal treatment. IMPORTANCE COVID-19 and flu are two respiratory illnesses which share similar clinical symptoms. The BD Veritor SARS-CoV-2/Flu assay has high sensitivity and specificity for detecting the SARS-CoV-2 and influenza A/B, the two etiologic agents causing COVID-19 and flu, respectively. This dual detection capability is critical when overlap occurs between the COVID-19 pandemic and the flu season. This triplex assay will allow efficient differentiation between the two respiratory illnesses and support a point-of-care physician diagnosis to facilitate the proper treatment and disease management for patients exhibiting overlapping symptoms.


Subject(s)
COVID-19 , Influenza, Human , COVID-19/diagnosis , COVID-19 Testing , Humans , Influenza, Human/diagnosis , Pandemics , Point-of-Care Systems , Retrospective Studies , SARS-CoV-2 , Sensitivity and Specificity
2.
J Clin Microbiol ; 59(1)2020 12 17.
Article in English | MEDLINE | ID: covidwho-991754

ABSTRACT

The clinical performance of the BD Veritor System for Rapid Detection of SARS-CoV-2 nucleocapsid antigen (Veritor), a chromatographic immunoassay used for SARS-CoV-2 point-of-care testing, was evaluated using nasal specimens from individuals with COVID-19 symptoms. Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO], ≥18 years of age) were utilized to compare Veritor with the Lyra SARS-CoV-2 PCR assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO, ≥18 years of age) were utilized to compare performance of Veritor to that of the Sofia 2 SARS Antigen FIA test (Sofia 2). The positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. In study 1, the PPA for Veritor, compared to Lyra, ranged from 81.8 to 87.5% across the 0 to 1 and 0 to 6 DSO ranges. In study 2, Veritor had PPA, NPA, and OPA values of 97.4, 98.1, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Veritor met FDA emergency use authorization (EUA) acceptance criteria for SARS-CoV-2 antigen testing for the 0 to 5 and 0 to 6 DSO ranges (PPA values of 83.9% and 82.4%, respectively). Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test allows for more rapid COVID-19 testing utilizing easy-to-collect nasal swabs but demonstrated <100% PPA compared to PCR.


Subject(s)
Antigens, Viral/analysis , COVID-19 Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/analysis , Spike Glycoprotein, Coronavirus/analysis , Adult , Female , Humans , Immunoassay/methods , Male , Middle Aged , Nasopharynx/virology , Oropharynx/virology , Point-of-Care Testing , Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity